H62004700 8 Ch High Power General Purpose Relay Switch

Download the Catalogue. H62004700 8x SPST 12A-250VAC 24VDC relays 8 relays SPST (2�4) normally closed. Switching up to 250 Vac and 12A YAV90304 required. CAN Control (or Ethernet with Ethernet to CAN Gateway) Drivers dll & VIs available Eight relays organized in two trees of four with two relays (One in each tree) with NC contact available. The module is shielded in order to reduce the radiated interference in high current switching.

Lees verderH62004700 8 Ch High Power General Purpose Relay Switch

YAV90059 Very High Density Multiconfiguration Mux

Download the Catalogue. YAV90059 configureerbare multiplexer. ? 128 to 16 Mux ? 8 Banks 16 Channel 1 Pole ? 8 Banks 8 Channel 2 Pole ? 2A/250VAC ? Max. switching 62,5VA ? CAN bus ? Form G   The YAV90059 module can be configured in different ways depending the application needed: from 8-bank, 16-channel, 1 pole to 8-bank, 8-channel, 2 pole, or also 128 Channel 1-pole among other possibilities. It uses high quality electro-mechanical relays allowing each channel to switch…

Lees verderYAV90059 Very High Density Multiconfiguration Mux

H7300351A HV (High Voltage 5kV) Switching matrix 19 inch

H7300351A (High Voltage Mux 1�4 Ch with discharge. relay 5KV) 48ch HV 15Kv switching, integrated. ? CAN bus controlled HV switching matrix ? Hipot test up to 15kV ? NC relay for discharge resistor ? Power up and High Voltage indications ? Customized configuration options ? Compact size: 19? rack 1U height This switching matrix enables the switching between different test poinits, when performing dielectric strenght test and Hipot test. It is featuring High Voltage relays,…

Lees verderH7300351A HV (High Voltage 5kV) Switching matrix 19 inch

H73000900 Power Supply 510W 5V40/2x12V20/24V3 19

This 1U 19? power unit consists of a configurable modular power supply. It has 4 slots, so it?s configurable to meet your specific test system power�needs (in addition to the set-up example shown here). All output power is available via the back of the unit using a VPC mass Interconnect I1 or Icon interface. H73000900 sample priced configuration ; Outputs: 5V/40A; 2x12V/20A; 24V/3A Can controlled on/off Includes a VPC I1 or iCON mass interconnect. I sense…

Lees verderH73000900 Power Supply 510W 5V40/2x12V20/24V3 19

H730008xS Switched Power distributed module, CAN control

H730008xS ? Controlled start up of test systems ? 70 A maximum total current to distribute (Power IN/OUT Connectors) ? Different socket types (Standards depending on country area) ? Standard 19? rack 2UA ? 8 or 4 sockets (depending on plug type), 240Vac ? Power up cable included (for connection from MMI) The intelligent Power Distribution Unit (PDU) H7300.08xx has two main functions: ? Distributing the power to each device in a system ? Switching on…

Lees verderH730008xS Switched Power distributed module, CAN control

H73000700 Power Management & MMI module

H73000700 ? Standard 19? rack ? Universal AC input 24VDC8A power supply with intelligent temperature control ? Platform Safety Management meeting EN 60947-5-1, EN 60204 and VDE 0113-1 requirements. ? Microcontroller with RTOS ? Local and remote temperature measurement with standard Pt100 sensors ? Platform temperature control with controlled fans. ? 1x DB-9 connector CAN bus port for direct connection to NI CAN interfaces ? 4x Four-pole terminal blocks as CAN bus control ports (with 1500V…

Lees verderH73000700 Power Management & MMI module

H73000301 Power management & MMI module Lite version

H73000301 ? 2U height x 305mm depth ? 24Vdc 8A Power Supply ? 230Vac 15A Contactors ? AC Current & Power Factor measurement ? 2x Temp. Measurement ? Cooling fans control ? 2x M12 I/O?s connector ? External Stop and RST ? 5x CAN bus ports ? 1x LAN Ethernet ? 1x RS485 ? 1x USB ? 1x Safety Relay x2 Outputs ? Alarm buzzer This module, named ?6TL-MMI Lite version?, is designed to be the…

Lees verderH73000301 Power management & MMI module Lite version

YAVCANCON2 CAN bus counter/register

YAVCANCON2 Features ? Two independent counters with data storage when not powered ? Used to store fixture data ? 1 input for cycle counting and 1 input for automatic cycle starting ? CAN bus controlled ? Left and Right LEDs Download the Catalogue. Applications ? Fixture identification ? Spring loaded probes cycle counting ? Automatic cycle start up when detecting the contact of the pressure system ? Storage of conveyor set-up information This module is designed…

Lees verderYAVCANCON2 CAN bus counter/register

YAV90304 8 in/16 out CAN bus module

YAV90304 Features ? 8x 24VDC PNP Inputs (or TTL) ? 16x 24VDC PNP Outputs (up to 500mA or TTL) ? DIP switch Address setting ? Interfaz CAN bus Download the Catalogue. Applications ? Input & Output interface This module features outputs to control up to 16 loads and 8 inputs to simplify the control of devices that are located inside the test fixture and/or test platforms. Ask for P/N YAV90304T, for in/out TTL level.

Lees verderYAV90304 8 in/16 out CAN bus module

YAV90321 48 Optocoupled digital inputs

Download the Catalogue.   YAV90321 Schematics YAV90321 Description and main features The Optocoupled Digital Inputs module is based on: ? Microcontroller sub-module that contents all the logic and interface ? Main board with mass connection interface allocating 48 optocoupled inputs Board Serial number (S/N) appears in the board label and is also recorded into the microcontroller non erasable memory.   General features ? 48 Digital Optocoupled Inputs ? Integrated Clamp Diode for overvoltage protection ? Wide…

Lees verderYAV90321 48 Optocoupled digital inputs

YAV90048 48 Optocoupled open Drain 42V-6A DOs

YAV90048 Description and main features The Optocoupled Digital outputs module is based on: ? Microcontroller sub-module that contents all the logic and interface ? Main board with mass connection interface allocating six isolated blocks with 8 protected outputs each. Download the Catalogue. General features ? 48 Digital Outputs NPN distributed on 6 banks with independent power supply and common. ? Thermal Shutdown with Automatic Restart and Overvoltage Protection ? Integrated Clamp for Inductive Switching ? Wide…

Lees verderYAV90048 48 Optocoupled open Drain 42V-6A DOs